Features
Console,
monitoring function
Up to 16 units of controllers connectable!
Up to 16 units of controllers can be connected to one LMD-100.
For wiring between
the LMD and controllers, only communication wiring is required,
thus reducing wiring.
Simple initial setting!
Initial setting for the LMD-100: Just set the controller
model and number of connected units.
Initial setting for the controllers: Set instrument number and
communication speed.
8 controller models connectable!
JCS-33A, JCM-33A, JCR-33A, JCD-33A:
Can be used together.
JCL-33A, DCL-33A, NCL-13A, ACS-13A: Cannot be used together.
| DCL-33A |
|
NCL-13A |
|
ACS-13A |
 |
|
 |
|
 |
|
|
|
|
|
| JC series (JCL-33A, JCS-33A,
JCM-33A, JCR-33A, JCD-33A from the left) |
 |
System configuration
System configuration example 1
@LMD-100 + DCL-33A

LMD-100
+ NCL-13A

LMD-100
+ ACS-13A

System configuration example 2
PC + IF-400 + LMD-100
+ DCL-33A

Console function!
Each set value can be set on the connected controllers.

The following 12 items can be set;
SV, Alarm 1, OUT1 proportional band, OUT2 proportional band,
Integral time,
Derivative time, ARW, OUT1 proportional cycle, OUT2 proportional
cycle,
Manual reset (only DCL-33A, NCL-13A, JCL-33A),
Set value lock, Auto-tuning/Auto-reset
Monitoring function!
Channel numbers of the connected controllers can be switched
manually or
automatically, and PV, SV and alarm status are displayed.

Data
logging function
Data such as PV, SV, OUT1 MV, OUT2 MV and controller status
(output, alarm, etc.)
of the controllers connected to the LMD-100 can be saved on
the CF card with
CSV format.
Data logging cycles are selectable from 1sec, 2sec, 5sec,
10sec, 15sec, 20sec,
30sec, 1min, 2min, 5min, 10min, 20min, 30min and 60min.
Easy operation!
1. Set Data logging conditions.
@@Date, time, logging item, logging cycle, etc. can be set
by keypad operation.
2. Insert the CF card.

3. Lock the LOCK switch.

4. Press the [LOG] key.

5. Data logging starts.
@@If Auto-start function is selected, data logging starts
at the set time.
Data for
approx. 4 months can be saved.
If data logging for all setting items is conducted
with 5 sec logging cycle by connecting
2 controllers, 1.7 to 2.0MB/24 hours CF card is used. Approx.
4 months of data can
be saved, using the CF card (256MB) included.
CF card data can be edited on commercially available spreadsheet
software.
(e.g.) Microsoft Excel

Set
value memory function
6 groups of SV of the connected controllers can be saved.
When changing SV frequently due to material or process
difference, this function
is very useful.
1. Registers SV of the Set value memory number in advance.
@(e.g.) If 5 units of controllers are connected, 30 types
of the SV can be registered as
@follows.
| Channel No. |
Set value
memory number |
| 1 |
2 |
3 |
4 |
5 |
6 |
| 1 |
100 |
200 |
150 |
125 |
140 |
230 |
| 2 |
110 |
210 |
170 |
135 |
150 |
230 |
| 3 |
120 |
220 |
190 |
120 |
150 |
220 |
| 4 |
130 |
230 |
210 |
120 |
160 |
220 |
| 5 |
140 |
240 |
230 |
100 |
160 |
210 |
2. Select Set value memory
number 3.
@Controllers' SV will be changed to the SV of Set value memory
number 3 (yellow
@section of the above table).

Broadcast
setting function
The same set value can be set to all connected controllers
simultaneously.
Press the [CH] key for approx. 1 sec in the Main setting
mode (*1) or Sub setting
mode (*2). The unit enters Broadcast setting status, and the
same set value will be
set to all connected controllers simultaneously.
To release Broadcast setting function, press the [CH] key for
approx. 1 sec again.
(*1) Main setting mode
SV, Alarm 1, OUT1 proportional band, OUT2 proportional band,
Integral time,
Derivative time, ARW, OUT1 proportional cycle, OUT2 proportional
cycle,
Manual reset (only DCL-33A, NCL-13A, JCL-33A)
(*2) Sub setting mode
Set value lock, Auto-tuning/Auto-reset

2-point
External operation input,
1-point Error output
2-point External operation input!
Logging Start/Stop and Front key Lock/Unlock can be switched
by external
operation.
Logging Start/Stop
External operation input LOG terminals
19-20 Closed (From Open to Closed): Logging Start
External operation input LOG terminals
19-20 Open (From Closed to Open): Logging Stop
Front key Lock/Unlock
External operation input LOG terminals
18-20 Closed (From Open to Closed): Front key Lock
External operation input LOG terminals
18-20 Open (From Closed to Open): Front key Unlock
If front key "LOCK" is selected, keys which are
related to the setting mode cannot
be operated.
1-point Error output!
If errors occur during data logging, if the CF card is defective,
when the LMD-100
battery runs down, or if the LOG key is pressed without setting
time, ERR output is
turned ON.

To the top of this page
Specifications
Rating
| Supply voltage |
100 to 240V AC 50/60Hz |
| Allowable fluctuation range |
85 to 264V AC |
General structure
| Dimensions |
96 x 96 x 100mm (W x H x D)
When using a water-proof cover: 115.6x131.7x100mm (WxHxD) |
| Mounting |
Flush |
| Case |
Flame-resistant cover, Color: Light gray |
| Panel |
Membrane sheet |
| Display |
PV display: PV (process variable) is displayed.
7 segments Red LED display 4 digits
Character size: 14.3 x 8.0mm (H x W)@@@@
|
SV display: SV (desired value) is displayed.
7 segments Green LED display 4 digits
Character size: 10.0 x 5.6mm (H x W)@@@@@@@@ |
|
CH display: Channel No. is displayed.
7 segments Yellow LED display 2 digits
Character size: 10.0 x 5.6mm (H x W)
|
|
MEMO display: Set value memory No. is displayed.
7 segments Yellow LED display 1 digit
Character size: 10.0 x 5.6mm (H x W)
|
Indicating performance
External memory storage
| Media |
CF card (Type I), Max. capacity: 2GB |
| Format |
FAT16 |
| Writing method |
Writing in a new file
Opens a new file every time logging starts, and saves
data in it.
When logging data reaches 65,000 lines, the file is closed,
and saves the data in a new file.
If a defective CF card is inserted, the reset function
to prevent malfunction is initiated, and the instrument
reverts to warm-up status.
Max. number of files: 170
If the number of files exceeds 170, an error message
appears on the PV display regardless of the remaining
memory capacity in the CF card.
|
| CF
card usage |
If data logging
for all setting items is conducted with a 5sec logging
cycle by connecting 2 controllers, 1.7 to 2.0MB/24 hours
CF cards are used. |
Standard functions
Console/
Logging function |
Console: Set values can be read and set to the controllers
by connecting a
@maximum of 16 units of controllers in Serial communication
(RS-485).
Logging: The LMD-100 constantly reads data from the
connected controllers,
@and writes it on the CF card every logging cycle.
Controllers: DCL-33A, JCS-33A, JCR-33A, JCD-33A, JCM-33A,
@NCL-13A, JCL-33A, ACS-13A (Default: DCL-33A)
Logging cycle: 1sec, 2sec, 5sec, 10sec, 15sec, 20sec,
30sec,
@1min, 2min, 5min, 10min, 20min, 30min, 60min. (Default:
10sec)
Logging item: Selects "Effective" or "Not
effective" for PV, SV,
@OUT1 MV, OUT2 MV and Controller status.
@(Default: PV: "Effective", Others: "Not
effective")
|
Serial
communication
(LMD-100 - Controllers) |
Communication line: RS-485
Communication method: Half-duplex communication start-stop
@synchronization
Communication speed: 19200bps
Communication protocol: Shinko protocol
Data format: Start bit 1, Data bit 7, Parity Even parity,
Stop bit 1
Sending data: SV, Alarm 1 value, OUT1 proportional band,
OUT2
@proportional band, Integral time, Derivative time,
ARW,
@OUT1 proportional cycle, OUT2 proportional cycle,
@Manual reset, Set value lock, Auto-tuning/Auto-reset
Receiving data: Receives the following data including
the Sending data.
@PV, OUT1 MV, OUT2 MV, controller status.
|
External
operation input
(Edge action) |
Logging Start/Stop and Front key LOCK/UNLOCK can be
switched using External contact.
Circuit current when closed: 6mA
|
| ERR
output |
If errors occur during data logging, if the CF card
is defective, when the LMD-100 battery runs down, or
if the LOG key is pressed without setting time, ERR
output is turned ON.
Action: ON/OFF action
Output: Relay contact 1a
Control capacity: 3A 250V AC (resistive load)
Electrical life: 100,000 times
|
| Auto-start |
Logging automatically performs
within auto-start and end time. |
| Set value memory |
Up to 6 groups of SV for the
connected controllers can be saved. |
| Broadcast setting |
The same set value can be set
to all connected controllers simultaneously. |
| Attached functions |
CF card LOCK switch, Power failure countermeasure,
Self-diagnosis, Warm-up indication, Error indications,
Momentary power failure indication |
Optional functions
Serial
communication
(Host -LMD-100)
(C5 option) |
Data of the LMD-100 and the connected controller can
be read and set from the external computer or PLC, etc.
Cable length: Max. 1.2km
Cable resistance: Within 50
(Terminator is not necessary or 120
or more on one side.)
Communication line: RS-485
Communication method: Half-duplex communication start-stop
synchronization
Communication speed: 9600bps, 19200bps (Default: 9600bps)
Code form: ASCII, Binary
Error correction: Command request repeat system
Error detection: Parity check, checksum
Communication protocol: Shinko protocol
Data format: Start bit 1, Data bit 7, Parity Even parity,
Stop bit 1
Instrument number: 0 to 95 (Default: 0)
|
Dust-proof/
Drip-proof
(IP option) |
Dust-proof/Drip-proof specification waterproof
cover (IP66) |
Terminal cover
(TC option) |
Electrical shock protection terminal cover |
Color
(BK option) |
Front panel frame and case: Black |
Insulation, Dielectric strength
| Insulation resistance |
10M
or more, at 500V DC |
| Dielectric
strength |
Power terminal - Communication terminal: 1.5kV AC for
1 minute
Power terminal - Output terminal: 1.5kV AC for 1 minute
Communication terminal - Output terminal: 1.5kV AC for
1 minute
|
Others
| Power consumption |
Approx. 6VA |
| Ambient temperature |
0 to 50 |
| Ambient humidity |
35 to 85%RH (Non-condensing) |
| Weight |
Approx. 400g |
| Accessories |
Mounting brackets: 1 set
Instruction manual: 1 copy
CF card (256MB): 1
Waterproof cover (When IP option is added): 1 piece
Terminal cover (When TC option is added): 2 pieces
|