Shinko Technos is a manufacturer of various equipment for temperature and humidity control. Site map
Inquiries
SHINKO TECHNOS CO.,LTD
ENGLISH
„ Company profile „ Contact„ HOME„ 
Usage selection
High accuracy control
General-purpose control
Cost-effective control
System control
Recording
New Products
Shinko Products
Digital indicating controllers
Digital temp. indicating controllers
DIN rail mounted controllers
Analog temperature controllers
Digital indicators
Hand-held thermo-hygrometer
Process controllers
Programmable controllers
Multi-point temperature control system
Communication type temp. control unit
Console/data logger
2ch digital data logger
Portable controllers
Oven temperature control equipment
Recorders
Humidity detectors
Hygrothermo detectors
Infrared thermocouples
Controllers for infrared thermocouples
Radiation thermometers
Signal conditioners
Remote I/O
Communication converters
Actuators
Level switch
Calibrator
Download
Catalogs
Manuals
Software
CAD data
Catalogs

Console/Data logger
LMD-100 (96mm x 96mm)

Features
EConsole, monitoring function
EData logging
ESet value memory function
EBroadcast setting
E2 points of External operation input, 1 point of Error output


Specifications    Dimensions

LMD-100_photo

Features

Console, monitoring function

Up to 16 units of controllers connectable!
Up to 16 units of controllers can be connected to one LMD-100. For wiring between
the LMD and controllers, only communication wiring is required, thus reducing wiring.

Simple initial setting!
Initial setting for the LMD-100: Just set the controller model and number of connected units.
Initial setting for the controllers: Set instrument number and communication speed.

8 controller models connectable!
JCS-33A, JCM-33A, JCR-33A, JCD-33A: Can be used together.
JCL-33A, DCL-33A, NCL-13A, ACS-13A: Cannot be used together.


DCL-33A NCL-13A ACS-13A
DCL-33A_photo NCL-13A_photo ACS-13A_photo
JC series (JCL-33A, JCS-33A, JCM-33A, JCR-33A, JCD-33A from the left)
JC_series_photo

System configuration
System configuration example 1
@LMD-100 + DCL-33A
    
          LMD-100+DCL-33A


      LMD-100 + NCL-13A
          LMD-100+NCL-13A


      LMD-100 + ACS-13A
          LMD-100+ACS-13A


    System configuration example 2
      PC + IF-400 + LMD-100 + DCL-33A
          PC+IF-400+LMD-100+DCL-33A


Console function!
Each set value can be set on the connected controllers.

          LMD-100_console_function

The following 12 items can be set;
SV, Alarm 1, OUT1 proportional band, OUT2 proportional band, Integral time,
Derivative time, ARW, OUT1 proportional cycle, OUT2 proportional cycle,
Manual reset (only DCL-33A, NCL-13A, JCL-33A),
Set value lock, Auto-tuning/Auto-reset



Monitoring function!
Channel numbers of the connected controllers can be switched manually or
automatically, and PV, SV and alarm status are displayed.

          LMD-100_monitoring_function


Data logging function

Data such as PV, SV, OUT1 MV, OUT2 MV and controller status (output, alarm, etc.)
of the controllers connected to the LMD-100 can be saved on the CF card with
CSV format.

Data logging cycles are selectable from 1sec, 2sec, 5sec, 10sec, 15sec, 20sec,
30sec, 1min, 2min, 5min, 10min, 20min, 30min and 60min.


  Easy operation!
    1. Set Data logging conditions.
@@Date, time, logging item, logging cycle, etc. can be set by keypad operation.


    2. Insert the CF card.
          LMD-100_CF_card_insertion

    3. Lock the LOCK switch.

          LMD-100_Lock_switch
4. Press the [LOG] key.

          LMD-100_Log_key

    5. Data logging starts.
@@If Auto-start function is selected, data logging starts at the set time.



Data for approx. 4 months can be saved.
If data logging for all setting items is conducted with 5 sec logging cycle by connecting
2 controllers, 1.7 to 2.0MB/24 hours CF card is used. Approx. 4 months of data can
be saved, using the CF card (256MB) included.


CF card data can be edited on commercially available spreadsheet software.
(e.g.) Microsoft Excel

             LMD-100_EXCEL


Set value memory function

6 groups of SV of the connected controllers can be saved.
When changing SV frequently due to material or process difference, this function
is very useful.

1. Registers SV of the Set value memory number in advance.
@(e.g.) If 5 units of controllers are connected, 30 types of the SV can be registered as
@follows.

Channel No. Set value memory number
1 2 3 4 5 6
1  100   200   150   125   140   230 
2  110  210  170  135  150  230
3  120  220  190  120  150  220
4  130  230  210  120  160  220
5  140  240  230  100  160  210

2. Select Set value memory number 3.
@Controllers' SV will be changed to the SV of Set value memory number 3 (yellow
@section of the above table).

          LMD-100_Set_value_memory_number_1


Broadcast setting function

The same set value can be set to all connected controllers simultaneously.
Press the [CH] key for approx. 1 sec in the Main setting mode (*1) or Sub setting
mode (*2). The unit enters Broadcast setting status, and the same set value will be
set to all connected controllers simultaneously.
To release Broadcast setting function, press the [CH] key for approx. 1 sec again.

(*1) Main setting mode
SV, Alarm 1, OUT1 proportional band, OUT2 proportional band, Integral time,
Derivative time, ARW, OUT1 proportional cycle, OUT2 proportional cycle,
Manual reset (only DCL-33A, NCL-13A, JCL-33A)
(*2) Sub setting mode
Set value lock, Auto-tuning/Auto-reset

         LMD-100_Set_value_memory_number_2


2-point External operation input,
1-point Error output


2-point External operation input!
Logging Start/Stop and Front key Lock/Unlock can be switched by external
operation.

Logging Start/Stop
External operation input LOG terminals
19-20 Closed (From Open to Closed): Logging Start
External operation input LOG terminals
19-20 Open (From Closed to Open): Logging Stop

Front key Lock/Unlock
External operation input LOG terminals
18-20 Closed (From Open to Closed): Front key Lock
External operation input LOG terminals
18-20 Open (From Closed to Open): Front key Unlock
If front key "LOCK" is selected, keys which are related to the setting mode cannot
be operated.


1-point Error output!
If errors occur during data logging, if the CF card is defective, when the LMD-100
battery runs down, or if the LOG key is pressed without setting time, ERR output is
turned ON.

    
      LMD-100_error_output

To the top of this page



Specifications

Rating

Supply voltage 100 to 240V AC 50/60Hz
Allowable fluctuation range 85 to 264V AC

General structure

Dimensions 96 x 96 x 100mm (W x H x D)
When using a water-proof cover: 115.6x131.7x100mm (WxHxD)
Mounting Flush
Case Flame-resistant cover, Color: Light gray
Panel Membrane sheet
Display

PV display: PV (process variable) is displayed.
7 segments Red LED display 4 digits
Character size: 14.3 x 8.0mm (H x W)@@@@

SV display: SV (desired value) is displayed.
7 segments Green LED display 4 digits
Character size: 10.0 x 5.6mm (H x W)@@@@@@@@

CH display: Channel No. is displayed.
7 segments Yellow LED display 2 digits
Character size: 10.0 x 5.6mm (H x W)

MEMO display: Set value memory No. is displayed.
7 segments Yellow LED display 1 digit
Character size: 10.0 x 5.6mm (H x W)


Indicating performance
Time Setting accuracy: Within 0.5%1sec
Clock

Time indication: 24-hour clock
Time error: Within 60sec/Month (at 25 ambient temperature)
Power failure guarantee: Backs up with lithium battery.
Lithium battery life: Lasts more than 10 years (at 20 ambient temperature)


External memory storage
Media CF card (Type I), Max. capacity: 2GB
Format FAT16
Writing method Writing in a new file
Opens a new file every time logging starts, and saves data in it.
When logging data reaches 65,000 lines, the file is closed, and saves the data in a new file.

If a defective CF card is inserted, the reset function to prevent malfunction is initiated, and the instrument reverts to warm-up status.
Max. number of files: 170

If the number of files exceeds 170, an error message appears on the PV display regardless of the remaining memory capacity in the CF card.

CF card usage If data logging for all setting items is conducted with a 5sec logging cycle by connecting 2 controllers, 1.7 to 2.0MB/24 hours CF cards are used.

Standard functions
Console/
Logging function

Console: Set values can be read and set to the controllers by connecting a
@maximum of 16 units of controllers in Serial communication (RS-485).
Logging: The LMD-100 constantly reads data from the connected controllers,
@and writes it on the CF card every logging cycle.
Controllers: DCL-33A, JCS-33A, JCR-33A, JCD-33A, JCM-33A,
@NCL-13A, JCL-33A, ACS-13A (Default: DCL-33A)
Logging cycle: 1sec, 2sec, 5sec, 10sec, 15sec, 20sec, 30sec,
@1min, 2min, 5min, 10min, 20min, 30min, 60min. (Default: 10sec)
Logging item: Selects "Effective" or "Not effective" for PV, SV,
@OUT1 MV, OUT2 MV and Controller status.
@(Default: PV: "Effective", Others: "Not effective")

Serial communication
(LMD-100 - Controllers)

Communication line: RS-485
Communication method: Half-duplex communication start-stop
@synchronization
Communication speed: 19200bps
Communication protocol: Shinko protocol
Data format: Start bit 1, Data bit 7, Parity Even parity, Stop bit 1
Sending data: SV, Alarm 1 value, OUT1 proportional band, OUT2
@proportional band, Integral time, Derivative time, ARW,
@OUT1 proportional cycle, OUT2 proportional cycle,
@Manual reset, Set value lock, Auto-tuning/Auto-reset
Receiving data: Receives the following data including the Sending data.
@PV, OUT1 MV, OUT2 MV, controller status.

External operation input
(Edge action)

Logging Start/Stop and Front key LOCK/UNLOCK can be switched using External contact.
Circuit current when closed: 6mA

ERR output

If errors occur during data logging, if the CF card is defective, when the LMD-100 battery runs down, or if the LOG key is pressed without setting time, ERR output is turned ON.
Action: ON/OFF action
Output: Relay contact 1a
Control capacity: 3A 250V AC (resistive load)
Electrical life: 100,000 times

Auto-start Logging automatically performs within auto-start and end time.
Set value memory Up to 6 groups of SV for the connected controllers can be saved.
Broadcast setting The same set value can be set to all connected controllers simultaneously.
Attached functions CF card LOCK switch, Power failure countermeasure,
Self-diagnosis, Warm-up indication, Error indications,
Momentary power failure indication

Optional functions
Serial communication
(Host -LMD-100)
(C5 option)

Data of the LMD-100 and the connected controller can be read and set from the external computer or PLC, etc.
Cable length: Max. 1.2km
Cable resistance: Within 50 (Terminator is not necessary or 120 or more on one side.)
Communication line: RS-485
Communication method: Half-duplex communication start-stop synchronization
Communication speed: 9600bps, 19200bps (Default: 9600bps)
Code form: ASCII, Binary
Error correction: Command request repeat system
Error detection: Parity check, checksum
Communication protocol: Shinko protocol
Data format: Start bit 1, Data bit 7, Parity Even parity, Stop bit 1
Instrument number: 0 to 95 (Default: 0)

Dust-proof/
Drip-proof
(IP option)
Dust-proof/Drip-proof specification waterproof cover (IP66)
Terminal cover
(TC option)
Electrical shock protection terminal cover
Color
(BK option)
Front panel frame and case: Black

Insulation, Dielectric strength
Insulation resistance 10M or more, at 500V DC
Dielectric strength

Power terminal - Communication terminal: 1.5kV AC for 1 minute
Power terminal - Output terminal: 1.5kV AC for 1 minute
Communication terminal - Output terminal: 1.5kV AC for 1 minute


Others
Power consumption Approx. 6VA
Ambient temperature 0 to 50
Ambient humidity 35 to 85%RH (Non-condensing)
Weight Approx. 400g
Accessories

Mounting brackets: 1 set
Instruction manual: 1 copy
CF card (256MB): 1
Waterproof cover (When IP option is added): 1 piece
Terminal cover (When TC option is added): 2 pieces


To the top of this page



Dimensions

  Dimensions (Scale: mm)
    LMD-100_Dimensions
                                                 


   Panel cutout (Scale: mm)
    LMD-100_Panel_cutout
Lateral close mounting
n: Number of units mounted

@

To the top of this page


Download Catalogs Contact

„ High accuracy control„ General-purpose control„ Cost-effective control„ System control „ Recording„ 
„ CE marking conformity„ UL approved products„ RoHS directive„ 
„ Company profile „ Contact„ Privacy policy „ HOME„ 
SHINKO TECHNOS CO.,LTD.@Head office:2-5-1, Senbahigashi, Minoo, Osaka, Japan 562-0035
@ JAPAN Overseas division Tel: +81-72-727-6100 Fax: +81-72-727-7006
@ Netherlands SHINKO EUROPE B.V. Tel: +31 73 5111182
Fax: +31 73 5111183
@ Canada SHINKO NORTH AMERICA CO.,LTD. Tel: +1-604-463-3309 Fax: +1-604-463-3307
@ China JIDONG SHINKO AUTOMATIC CONTROL
ENGINEERING (SHANGHAI) CO.,LTD.

Tel: +86-21-52829861 Fax: +86-21-52829863
Copyright (C) 2003-2011 Shinko Technos Co., Ltd. All Rights Reserved.