| Measuring system |
: |
Infrared radiation thermometer |
| Detecting element |
: |
IRT-100 series:
Thermopile |
|
|
IRT-200 series:
Si |
|
|
IRT-300 series:
Thermopile |
| Measuring range |
: |
IRT-100-TF:
-30 to 350 |
|
|
IRT-100-TA: -40 to 500 |
|
|
IRT-200-HS:
600 to 2000 |
|
|
IRT-300-AT:
-50 to 1000 |
|
|
IRT-300-AS: 600 to 3000 |
| Measuring wave length |
: |
IRT-100 series:
8 to 14 m |
|
|
IRT-200 series:
0.9 m |
|
|
IRT-300 series : 8
to 13 m
or 0.96 m |
| Response speed |
: |
IRT-100 series:
0.8sec |
|
|
IRT-200 series:
0.2sec |
|
|
IRT-300 series: 1sec
or 0.5sec |
| Emissivity compensation |
: |
IRT-100-TF: [0.95/0.80/1.00]
switchable |
|
|
IRT-100-TA: [0.95/0.80/0.30
to 1.90] switchable |
|
|
(0.01 setting/step) |
|
|
IRT-200 series:
0.100 to 1.900 |
|
|
IRT-300 series:
0.10 to 1.00 |
|
|
(0.01 setting/step) |
| Weight |
: |
IRT-100-TF: Approx.
160g |
|
|
IRT-100-TA: Approx.
180g |
|
|
IRT-200 series: Approx.
350g |
|
|
IRT-300 series: Approx.
700g |