20ch Temperature Control Board
ATCB-13A-20S/E (Discontinued)

Discontinued Products


 
-20ch temperature control in a compact board!
-Console panel can be installed in an easily accessible location!
-High/Low limit temperature alarms are standard
-Customized orders available!
ATCB-13A-20S/E_photo

 

Features

20ch temperature control in a compact board!
 
20ch temperature control function, all in a compact control board; 254x224x41mm(WxHxD)
ATCB-13A-20S/E_Control board_photo

Place a console panel in a convenient location!
 
Console panel (display, operation) and control board can be installed separately.
Length of connection cable: Approx. 30cm
    ATCB-13A-20S/E_Console panel_photo    

High/Low limit temperature alarm standard feature!
  Each channel has High/Low limit temperature alarms as standard.
Output is common to each channel.

Customized order available!
  Designable console panel, LED display or keys, etc. can be added.

TOP

Spec

Rating
 
Rated scale
Input range Resolution
0.0 to 500.0 0.1
32.0 to 932.0 0.1
Input Thermocouple: K, 20-point, for temperature control,
External resistance: 100 or less
Thermocouple: K, 1-point, for external temperature compensation,
External resistance: 100 or less
Supply voltage 24V DC
Allowable fluctuation range 10% of the supply voltage

General structure
 
Structure Console panel, Control board (Separable)
Dimensions Console panel: 152x100x17mm (WxHxD)
Control board: 254x224x41mm (WxHxD)
Mounting Console panel: Control panel surface
Control board: Internal control panel
Terminal arrangement Refer to the Names of sections.
Display Console panel:
 -Channel number display: Selected channel is indicated.
         7-segment, Red LED display, 2-digit
        Character size: 14.2x7.8mm (HxW)
 -PV display: PV (Process variable) is indicated.
        7-segment, Red LED display, 4-digit
        Character size: 14.2x7.8mm (HxW)
        (First decimal point from the right flashes during AT.)
 -SV display: SV (Desired value) is indicated.
        7-segment, Green LED display, 4-digit
        Character size: 14.2x7.8mm (HxW)
 -Alarm indicator (ALM)(Red): Lights when temperature alarm is ON. (Flashes in the alarm monitoring mode)
 -KEEP-WARM indicator (Green): Lights when heat-retention action is ON.
Control board:
Power supply (PWR) indicator (Green)
Communication(TX) indicator (Yellow)
Alarm (ALM) indicator (Red)
Ch1 output indicator(Green)
Ch2 output indicator(Green)
Ch3 output indicator(Green)
Ch4 output indicator(Green)
Ch5 output indicator(Green)
Ch6 output indicator(Green)
Ch7 output indicator(Green)
Ch8 output indicator(Green)
Ch9 output indicator(Green)
Ch10 output indicator(Green)
Ch11 output indicator(Green)
Ch12 output indicator(Green)
Ch13 output indicator(Green)
Ch14 output indicator(Green)
Ch15 output indicator(Green)
Ch16 output indicator(Green)
Ch17 output indicator(Green)
Ch18 output indicator(Green)
Ch19 output indicator(Green)
Ch20 output indicator(Green)

Lights when power-on.

Lights when sending data.

Lights when alarm output is ON
Lights when Ch1 output is ON.
Lights when Ch2 output is ON.
Lights when Ch3 output is ON.
Lights when Ch4 output is ON.
Lights when Ch5 output is ON.
Lights when Ch6 output is ON.
Lights when Ch7 output is ON.
Lights when Ch8 output is ON.
Lights when Ch9 output is ON.
Lights when Ch10 output is ON.
Lights when Ch11 output is ON.
Lights when Ch12 output is ON.
Lights when Ch13 output is ON.
Lights when Ch14 output is ON.
Lights when Ch15 output is ON.
Lights when Ch16 output is ON.
Lights when Ch17 output is ON.
Lights when Ch18 output is ON.
Lights when Ch19 output is ON.
Lights when Ch20 output is ON.


TOP

Setting structure
Setting method Console panel:
Setting by the Function keys
Control board (Refer to the Name of sections.)
DIP switch 1 (SW201)
No.
Item
ON
OFF
1
CH1
Control Allowed
Control Prohibited
2
CH2
Control Allowed
Control Prohibited
3
CH3
Control Allowed
Control Prohibited
4
CH4
Control Allowed
Control Prohibited
5
CH5
Control Allowed
Control Prohibited
6
CH6
Control Allowed
Control Prohibited
(Default: OFF for all channels)

DIP switch 2 (SW202)
No.
Item
ON
OFF
1
CH7
Control Allowed
Control Prohibited
2
CH8
Control Allowed
Control Prohibited
3
CH9
Control Allowed
Control Prohibited
4
CH10
Control Allowed
Control Prohibited
5
CH11
Control Allowed
Control Prohibited
6
CH12
Control Allowed
Control Prohibited
(Default: OFF for all channels)

DIP switch 3 (SW203)
No.
Item
ON
OFF
1
CH13
Control Allowed
Control Prohibited
2
CH14
Control Allowed
Control Prohibited
3
CH15
Control Allowed
Control Prohibited
4
CH16
Control Allowed
Control Prohibited
5
CH17
Control Allowed
Control Prohibited
6
CH18
Control Allowed
Control Prohibited
7
CH19
Control Allowed
Control Prohibited
8
CH20
Control Allowed
Control Prohibited
(Default: OFF for all channels)

Rotary switch (SW204)
Sets instrument number to discern controllers.
(Instrument number: 0-9, A-F)

DIP switch (SW205)
No.
Item
ON
OFF
1
Communication speed
19200bps
9600bps
2
Data length
8 bits
7 bits
3
Parity bit
No
Yes
4
Parity
Odd
Even
5
Stop bit
2bits
1bit
6
External temp. compensation
thermocouple
Used
Not used
7
Communication
error processing
Effective
Ineffective
8
Console indication
4-digit (with decimal point)
3-digit (without decimal point)
9
Protocol
Modbus RTU
Shinko protocol
10
Spare
(Default: 1: ON, Others: OFF)

Indicating performance
Indicating accuracy Within 0.1% of the input span1 digit (excluding cold junction temperature compensation accuracy.)
Default: Within 1.0 (at 252) (including cold junction temperature compensation accuracy)
Cold junction
temperature
compensation accuracy
2.0
Input sampling period 0.5sec

Control performance
Setting accuracy The same as the Indicating accuracy
Control action

-PID control (with AT function):
If AT continues after error assessment time has passed (after AT starting), AT stops.
PID values for the channel of which AT has stopped, will revert to the value before AT is performed.
-PI control: When derivative time is set to 0
-PD control (With Auto-reset function): When integral time is set to 0
-P control (With Auto-reset function): When integral and derivative time are set to 0
-ON/OFF control: When proportional band is set to 0.

-Proportional band (P): 0-50 or 0-100
(When 4-digit is selected: 0.0-50.0 or 0.0 -100.0)
-Integral time (I): 0-1000sec (Setting to 0 disables the function.)
-Derivative time (D): 0-300sec (Setting to 0 disables the function.)
-ARW: 0-100%
-Proportional cycle: 1-50sec
-ON/OFF hysteresis: 0.1-100.0 ()
-AT error assessment time: 1-240 minutes

Control output Ch1-Ch20: Non-contact voltage (for SSR drive), 12V DC15%
Max. 20mA DC
Ch8 (common to non-contact voltage output): Relay contact, 1a
Control capacity: 3A 250V AC(resistive load)
1A 250V AC(inductive load cos=0.4)
Electric life: 100,000 cycles
Integral computation
initial setting function
When control starts, optimum value of integral computation will be set as an initial value, based on the MV when control is stable.
Control ON
timing
asynchronous function
Prevents control output to be turned ON simultaneously.
During control, multiple channel outputs may be turned ON at one time, however, this function prevents their outputs to be turned ON synchronously.
Oil temperature control If Ch8 proportional band is set to 0, and if Direct action is selected during Direct/Reverse action selection, Ch8 will become oil temperature control.
(Default: Oil temperature control)
CH8 will become "Control allowed" status regardless of External input 1, DIP switches (SW201-SW203) and Control OUT/OFF selection.
Heater keep-warm control If External input 6 is turned ON (Closed), control is performed at Heater keep-warm value (common setting 100 or 212 to Ch1-Ch20).
SV and communication data will also become 100 or 212.
However, if Ch8 is assigned to oil temperature control (when Direct action is selected from Direct/Reverse action, and proportional band is set to 0), Heater keep-warm control is not available for Ch8.

TOP

Standard functions
Temperature alarm

High/Low limit temperature alarm action (Low limit alarm with standby)
(For CH8, only High limit alarm is available if it is for oil temperature control.)
-Action:
Alarm output is turned ON if one or more channel alarms are activated from Ch1 to Ch20.
If SV is changed, or if usual control/keep-warm control is switched, the unit returns to standby status again.
Alarm function will be disabled if Control output OUT/OFF is selected or if External input 1 or 2 is OFF (Control Prohibited).

-Output:
Relay contact, 1a
Control capacity: 3A 250V AC (resistive load)
Electrical life; 100,000 cycles

Serial communication

-Communication line: EIA RS-422A
-Communication method: Duplex communication
-Synchronization method: Start-stop synchronization
-Communication protocol: Shinko protocol, Modbus RTU protocol
(Default: Shinko protocol)
-Communication speed: 19200, 9600bps (Default: 19200bps)
-Data format:
Start bit: 1
Data bit: 7, 8 (Default: 7)
Parity bit: Yes, No (Default: Yes)
Parity: Even, Odd (Default: Even)
Stop bit: 1, 2 (Default: 1)
-Instrument number: 0-15 (Default: 0)

External operation input Photocoupler insulation input
External power supply: 24V DC10%
Input impedance: 20k
-External input 1:
ON (Closed): Block A (Ch1-Ch8) Control Allowed
OFF (Open): Control Prohibited
However, if Ch8 is of oil temperature control, Ch8 becomes "Control Allowed" status regardless of External input 1 status.
[If "Control Prohibited" is selected in the status of OFF (Open), 0 (zero) will be indicated on the PV display.]
-External input 2:
ON (Closed): Block B (Ch9-Ch20) Control Allowed OFF(Open): Control Prohibited
[If Control Prohibited is selected in the status of OFF(Open), 0 (zero) will be indicated on the PV display.]
-External input 3:
ON (Closed): Ch4, Ch5 are subject to Block B, and are operated under External input 2.
-External input 4:
ON (Closed): Ch6, Ch7 are subject to Block B, and are operated under External input 2.
-External input 5:
ON (Closed): Ch19, Ch20 are subject to Block A, and are operated under External input 1.
-External input 6:
ON (Closed): Performs Heater keep-warm control. However, if Ch8 is for oil temperature control, Heater "Keep-Warm" option is not available for Ch8.
Attached functions Sensor correction, PV filter time constant, Self-diagnosis, Automatic cold junction temperature compensation, Burnout, Underscale, Power failure countermeasure

Optional function
Output minus common
(COM option)
Output common from CH9 to CH20 will be changed to minus common.

Insulation, dielectric strength
Insulation resistance 10M or more, at 500V DC
Insulation test must not be carried out between input terminals.
Dielectric strength Input terminal - Ground terminal: 500V AC for 1 minute
Input terminal - Power terminal: 1.5kV AC for 1 minute
Output terminal- Power terminal: 1.5kV AC for 1 minute
Power terminal - Ground terminal: 1.5kV AC for 1 minute
Dielectric strength test must not be carried out between input terminals.

Other
Power consumption Approx. 15W
Ambient temperature 0 to 50
Ambient humidity 35 to 85%RH (Non-condensing)
Weight Approx. 1350g

TOP

Names of Sections

Console panel (Display, operation)
ATCB-13A-20S/E_Console panel

Control board
ATCB-13A-20S/E_Control board

Connector, Modular jack
ATCB-13A-20S/E_Connector_CN201

ATCB-13A-20S/E_Connector_CN202

ATCB-13A-20S/E_Connector_CN203

ATCB-13A-20S/E_Connector_CN204


ATCB-13A-20S/E_Modular jack_MJ201

Products
Temperature & Programmable Controllers
Signal
Conditioners
System Products,
Comm. Converters
Indicators
Recorders,
Data Loggers

Portable, Other
Input Devices
Output Devices


TOP

Downloads Catalogs Contact

HOME | Company Profile | Quality & Environmental Activities | Products
Support & Downloads | Applications | Discontinued Products
CE conformity & UL Approved Products | RoHS Directive | Privacy Policy | Terms of Use
Japanese | Sitemap
Copyright (C) 2003-2018 Shinko Technos Co., Ltd. All Right Reserved.