Usage selection
High accuracy control
General-purpose control
Cost-effective control
System control
Recording
New Products
Shinko Products
Digital indicating controllers
Digital temp. indicating controllers
DIN rail mounted controllers
Analog temperature controllers
Digital indicators
Hand-held thermo-hygrometer
Process controllers
Programmable controllers
Multi-point temperature control system
Communication type temp. control unit
Console/data logger
2ch digital data logger
Portable controllers
Oven temperature control equipment
Recorders
Humidity detectors
Hygrothermo detectors
Infrared thermocouples
Controllers for infrared thermocouples
Radiation thermometers
Signal conditioners
Remote I/O
Communication converters
Actuators
Level switch
Calibrator
Download
Catalogs
Manuals
Software
CAD data
Catalogs

Digital Indicating Controllers
ACD-13A (96 x 96mm)
ACR-13A (48 x 96mm)

ON/OFF SERVO Digital Indicating Controllers
ACD-15A (96 x 96mm)
ACR-15A (48 x 96mm)

◆Features

Industry leading large LCD display!

PV viewable even during control OFF

MV viewing on the bar graph

Simplified setting mode usable

A variety of I/O Event functions

Power via USB cable usable for setup

Feedback potentiometer Yes/No selectable

Drip-proof/Dust-proof



Spec Terminal arrangement Dimensions

Flyer (PDF file 617KB)

ACD-13A, ACR-13A spec sheet (PDF file 436KB)

ACD-15A, ACR-15A spec sheet (PDF file 365KB)

ACD,R-13A_photo





・Features

Clear, large LCD display-Enhanced visibility !

  Extra large LCD display
  ACD-13A
ACD-15A
PV display: 24.0 x 11.0mm (HxW)
SV/MV/TIME display: 14.0 x 7.0mm (HxW)
  ACR-13A
ACR-15A
PV display: 14.0 x 5.4mm (HxW)
SV/MV/TIME display: 10.0 x 4.6mm (HxW)
   
  Comparison with Shinko controller JCD-33A

ACD-13A, ACD-15A
ACD-13A_LCD_display

Shinko controller JCD-33A
JCD-33A_display





PV viewable even during control OFF !

  4 choices during control output OFF function
PV can be indicated even during control output OFF, and an alarm output can be selected as well.
  OFF indication
ACD-13A_Control_OFF_OFF
  PV indication
ACD-13A_Control_OFF_PV

To the top of this page





Output MV can be viewed on the bar graph

  22-segment (-5 to 105%) bar graph
DV indication is selectable.
  ACD-13A
ACD-13A_bar_graph
   




Simplified setting mode usable

  Basic settings and key operations are now doable via 3 key usage (Increase, Decrease, Mode key)
  ACD-13A_keys
   




A variety of Input/Output Event functions !

  Event input 4 points (option), Event output Max 5 points
 

Multiple Input/Output Event functions can be selected from; Alarm output, Heater burnout alarm output (option), Loop break alarm output, Timer output, Time signal output, Pattern end output, etc.

   

To the top of this page





Power via USB cable usable for setup

  If CMB-001 USB communication cable (sold separately) is used, a power supply for the controller is not necessary for initial settings.
  Console software (SWS-AC001M) displays
Console software(SWS-AC001M)
   




Feedback potentiometer "Yes/No" selectable

  Selectable using the front keypad. (ACD-15A, ACR-15A only)
   




Drip-proof/Dust-proof
  IP66 structure allows usage in harsh environments when the controller is exposed to water or dust.
   

To the top of this page





・Specifications

・Rating

Rated scale
Input Scale range Resolution
K -200 to 1370 -328 to 2498 1()
K -200.0 to 400.0 -328.0 to 752.0 0.1()
J -200 to 1000 -328 to 1832 1()
R 0 to 1760 32 to 3200 1()
S 0 to 1760 32 to 3200 1()
B 0 to 1820 32 to 3308 1()
E -200 to 800 -328 to 1472 1()
T -200.0 to 400.0 -328.0 to 752.0 0.1()
N -200 to 1300 -328 to 2372 1()
PL-U 0 to 1390 32 to 2534 1()
C(W/Re5-26) 0 to 2315 32 to 4199 1()
Pt100 -200.0 to 850.0 -328.0 to 1562.0

0.1()

-100.0 to 100.0 -148.0 to 212.0 0.1()
-100.0 to 500.0 -148.0 to 932.0 0.1()
-200 to 850 -328 to 1562 1()
JPt100 -200.0 to 500.0 -328.0 to 932.0 0.1()
-200 to 500 -328 to 932 1()
4 to 20mA -2000 to 10000 1
0 to 20mA -2000 to 10000 1
0 to 10mV -2000 to 10000 1
-10 to 10mV -2000 to 10000 1
0 to 50mV -2000 to 10000 1
0 to 100mV -2000 to 10000 1
0 to 1V -2000 to 10000 1
0 to 5V -2000 to 10000 1
1 to 5V -2000 to 10000 1
0 to 10V -2000 to 10000 1
Input Thermocouple K, J, R, S, B, E, T, N, PL-U, C(W/Re5-26)
External resistance: 100
RTD Pt100, JPt100 3-wire system
Allowable input lead wire resistance: 10 or less per wire
DC current 0-20mA DC, 4-20mA DC
Input impedance: 50, Allowable input current: 50mA or less
DC voltage 0-10mV DC, -10-10mV DC, 0-50mV DC, 0-100mV DC, 0-1V DC
Input impedance: 1M or more, Allowable input voltage: 5V DC or less
Allowable signal source resistance: 2k or less
0-5V DC, 1-5V DC, 0-10V DC
Input impedance: 100k or more, Allowable input voltage: 15V DC or less
Allowable signal source resistance: 100 or less
Supply voltage 100 to 240V AC 50/60Hz
24V AC/DC 50/60Hz
Allowable fluctuation range 85 to 264V AC
20 to 28V AC/DC

・General structure

External dimensions ACD-13A, ACD-15A: 96x96x110mm (WxHxD)
ACR-13A, ACR-15A: 48x96x110mm (WxHxD)
Mounting Flush
Display ACD-13A
ACD-15A
PV display: 24.0x11.0mm (HxW)
SV/MV/TIME display: 14.0x7.0mm (HxW)
ACR-13A
ACR-15A
PV display: 14.0x5.4mm(HxW)
SV/MV/TIME display: 10.0x4.6mm (HxW)

・Indication performance
Basic accuracy Thermocouple Within 0.2% of each input span1digit
However, R, S input -50 to 200(-58 to 392): Within 6 (12)
B input, 0 to 300 (0 to 572): Accuracy is not guaranteed
K, J, E, T, N input, Less than 0 (32): Within 0.4% of each input span1digit
RTD Within 0.1% of each input span1digit
DC current,
DC voltage
Within 0.2% of each input span1digit
External setting input accuracy Within 0.2% of each input span
Cold junction temperature compensation accuracy Within 1 at 0 to 50
Input sampling
period
0.125sec (When External setting input option is added: 0.25sec)
Time accuracy Within 1.0% of the setting time

・Control performance
Setting accuracy Based on the Basic accuracy and Cold junction temperature compensation accuracy
Control action

PID action (With Auto-tuning)
PI action: When derivative time is set to 0
PD action (With Auto, Manual reset function): When integral time is set to 0
P action (With Auto, Manual reset function): When integral and derivative time is set to 0
ON/OFF action: When proportional band is set to 0
Proportional band (P): 0 to Input span or (DC current, voltage input: 0.0 to 1000.0%)
Integral time (I): 0 to 3600sec
Derivative time (D): 0 to 1800sec
Proportional cycle: 1 to 120sec
ARW: 0 to 100%
ON/OFF action hysteresis: 0.1 to 1000.0 ()
Output high limit, low limit: 0 to 100% (DC current output: -5 to 105%)

Control output ACD-13A, ACR-13A
・Relay contact, 1a1b
・Non-contact voltage (for SSR drive)
・DC current

ACD-15A, ACR-15A
・Relay contact, 1ax2

・Standard functions

Event output

2 points of Event output

Selectable during Event output allocation by keypad
・Alarm output; High limit
・Alarm output; Low limit
・Alarm output; High/Low limits
・Alarm output; High/Low limits independent
・Alarm output; High/Low limit range
・Alarm output; High/Low limit range independent
・Alarm output; Process high
・Alarm output; Process low
・Alarm output; High limit with standby
・Alarm output; Low limit with standby
・Alarm output; High/Low limits with standby
・Alarm output; High/Low limits with standby independent
・Timer output
・Timer output (Control ON while timer ouput is ON)
・Heater burnout alarm output (When W option is added)
・Loop break alarm output
・Time signal output
・Output during AT
・Pattern end output

Console communication

By connecting the USB communication cable (CMB-001) to the Console connector
of the instrument, the following operations can be conducted from the external
computer using the Console software SWS-AC001M.
Console communication and Serial communication cannot be used together.
・Reading and setting of the SV, PID values and various set values
・Reading of the PV and action status
・Function change

Communication specifications
・Communication protocol: Shinko protocol
・Communication interface: C-MOS level
・Communication method: Half-duplex communication
・Synchronization method: Start-stop synchronization
・Communication speed: 9600bps
・Data bit: 7
・Parity: Even
・Stop bit: 1
・Exclusive cable

Attached functions Sensor correction, Set value lock, Auto/Manual switching, Program control, Set value ramp, Power failure countermeasure, Self-diagnosis, Automatic cold junction temperature compensation, Burnout, Input abnormality, Warm-up indication, PV color switching, Timer, Bar graph indication

・Optional functions
Event input
(EI option)

If this option and Serial communication (C, C5 option) are added together, Event input EVI3 and EVI4 cannot be used.

4 points of event input
Selectable during Event input allocation by keypad
・Set value memory function
・Control ON/OFF
・Direct/Reverse control action
・Timer function Start/Stop
・PV display; PV holding
・PV display; PV peak value holding
・Preset output
・Auto/Manual control
・Remote/Local
・Program mode; RUN/STOP
・Program mode; Holding/Not holding
・Program mode; Advance function
・Integral action holding

Event output
(EVT3 option)

(Only for ACD-13A, ACR-13A)
If this option is added, Heating/Cooling control (DR, DS, DA option) or Insulated power output (P24 option) cannot be added together.

EVT1 to EVT3 will be added using a common terminal.
Selectable by keypad during Event output allocation (the same as the standard Event output function)

Event output
(EVT5 option)

EVT4, EVT5 can be added.
Selectable by keypad during Event output allocation (the same as the standard Event output function)

Heater burnout alarm
(W option)
(Only for ACD-13A, ACR-13A)
Monitors heater current with CT (current transformer), and detects burnout.
Rated current: Single-phase; 20A, 100A, 3-phase; 20A, 100A
Setting range: 0.0 to 20.0A or 0.0 to 100.0A
Setting accuracy: Within 5% of the rated current
Action point: set value

Heating/Cooling control output
(Dx option)

(Only forACD-13A, ACR-13A)
If this option is added, Event output (EVT3 option) or Insulated power output (P24 option) cannot be added together.
If this option is added, Event output EVT2 cannot be used.

An action mode is selectable by front keypad.
・Air cooling: Linear characteristic
・Oil cooling: 1.5th power of the linear characteristic
・Water cooling: 2nd power of the linear characteristic

OUT2 output
・DR: Relay contact 1a1b
・DS: Non-contact voltage (for SSR drive)
・DA: DC current

Serial communication
( C, C5 option)
If this option and Event input (EI option) are added together, Event input EVI3 and EVI4 cannot be used.

The following operations can be carried out from the external computer.
・Reading and setting of the SV, PID values and various set values
・Reading of the PV and action status
・Function change

Communication specifications
・Communication line: C(EIA RS-232C), C5(EIA RS-485)
・Communication method: Half-duplex communication
・Synchronization method: Start-stop synchronization
・Communication speed: 9600, 19200, 38400bps (Selectable by keypad)
・Data bit: 7, 8
・Parity: Even, Odd, No parity
・Stop bit: 1or 2 (Selectable by keypad)
・Communication protocol: Shinko protocol, Modbus ASCII, Modbus RTU (Selectable by keypad)

Digital external setting via Shinko programmable controllers:
Receives the digital set values from the Shinko programmable controllers (PC-900, PCD-33A with SVTC option).
External setting input
(Ex option)

SV adds external analog signal to remote bias value.

Setting signal
・EA(4-20): DC current 4-20mA DC
・EA(0-20): DC current 0-20mA DC
・EV(1-5): DC voltage 1-5V DC
・EV(0-1): DC voltage 0-1V DC
Input sampling 0.25sec

Transmission output
(Tx option)

Converting the value (PV, SV, MV or DV transmission) to analog signal every 0.125
seconds, outputs the value in current or voltage.

Resolution: 1/12000
Output
・TA: DC current 4 to 20mA DC (load resistance Max. 500)
・TV: DC voltage 0 to 1V DC (load resistance Min.100k)
Output accuracy: Within 0.3% of the transmission output span
Insulated power output
(P24 option)
(Only for ACD-13A, ACR-13A)
If this option is added, Event output (EVT3 option) or Heating/Cooling control (DR, DS, DA option) cannot be added together.
If this option is added, Event output EVT2 cannot be used.

Output voltage: 243V DC (when load current is 30mA DC)
Ripple voltage: Within 200mV DC (when load current is 30mA DC)
Max load current: 30mA DC

・Insulation, Dielectric strength

Insulation resistance

10M or more, at 500V DC
When OUT1 and OUT2 are non-contact voltage or DC current output, OUT1 is
not insulated from OUT2.
Dielectric strength Between Power terminal - Ground: 1.5kV AC for 1minute
Between Input terminal - Ground: 1.5kV AC for 1minute
Between Input terminal - Power terminal: 1.5kV AC for 1minute

・Other
Ambient temperature 0 to 50
Ambient humidity 35 to 85%RH (Non-condensing)
Drip-proof /Dust-proof IP66 for the front panel

To the top of this page





・Terminal arrangement

  Terminal arrangement

ACD-13A
  ACD-13A_terminal
   
ACR-13A
  ACR-13A_terminal
   
ACD-15A
  ACD-15A_terminal
   
ACR-15A
  ACR-15A_terminal


 
To the top of this page




・External dimensions

  External dimensions (Scale: mm)

ACD-13A, ACD-15A
  ACD-13A_dimensions
   
ACR-13A, ACR-15A
  ACR-13A_dimensions


 Panel cutout (Scale: mm)
ACD-13A, ACD-15A
  ACD-13A_panel_cutout
   
ACR-13A, ACR-15A
  ACR-13A_panel_cutout


To the top of this page


Download Catalogs Contact

High accuracy controlGeneral-purpose controlCost-effective controlSystem control Recording
CE marking conformityUL approved productsRoHS directive
Company profile ContactPrivacy policy HOME
SHINKO TECHNOS CO.,LTD. Head office:2-5-1, Senbahigashi, Minoo, Osaka, Japan 562-0035
  JAPAN Overseas division Tel: +81-72-727-6100 Fax: +81-72-727-7006
  Netherlands SHINKO EUROPE B.V. Tel: +31 73 5111182
Fax: +31 73 5111183
  Canada SHINKO NORTH AMERICA CO.,LTD. Tel: +1-604-463-3309 Fax: +1-604-463-3307
  China JIDONG SHINKO AUTOMATIC CONTROL
ENGINEERING (SHANGHAI) CO.,LTD.

Tel: +86-21-52829861 Fax: +86-21-52829863
Copyright (C) 2003-2009 Shinko Technos Co., Ltd. All Rights Reserved.